Search results for "Lumbar spinal stenosis"
showing 7 items of 7 documents
Clinical analysis following lumbar interspinous devices implant: where we are and where we go
2014
Objectives:We present our experience with patients treated with interspinous devices who are affected by neurogenic intermittent claudication (NIC) or lumbar disc herniation (LDH) where the interspinous system has been inserted following microdiscectomy.Study design:Retrospective study.Methods:This study included patients (n=100) with NIC secondary to lumbar spinal stenosis (group 1), and patients (n=100) with LDH (group 2) in whom the interspinous device has been implanted following radicular decompression in a period spanning 6 years. The latter have been compared with a homogenous group of patients (n=100) where no interspinous system has been implanted following microdiscectomy (group 3…
High Rate of Studies with Level 1 and 2 Evidence among the 100 Most Cited Articles in Lumbar Spinal Stenosis.
2021
Abstract Background To date, no study has used bibliometric analysis to review the most influential articles in lumbar spinal stenosis. The objective of this study was to identify and analyze the characteristics and the level of evidence of the 100 most cited articles on lumbar spinal stenosis Methods The Thomson Reuters Web of Science was accessed to find the 100 most cited articles on lumbar spinal stenosis. For each article, we recorded the number and density of citations, authors, country, journals and years, department, level of evidence, type of study, and if it was part of any multicenter studies. Results Until January 2017, the 100 most cited articles accumulated 11,136 citations (a…
Walking Speed as an Alternative Measure of Functional Status in Patients with Lumbar Spinal Stenosis
2019
Objective The main objective was to compare estimated walking perimeter (WP) and actual WP during a free walking test (6-minute walk test [6MWT]) in patients with lumbar spinal stenosis (LSS). The second objective was to describe the correlation between measured gait parameters and functional parameters. Methods This was a single-center prospective study including 38 patients with symptomatic LSS (23 men, 15 women; mean age, 69.3 ± 7.9 years). The intervention was the 6MWT. For the main outcome measure, patients were first asked to verbally estimate their WP. Then, WP was evaluated using a 6MWT at a self-selected speed. In the absence of need to stop, and if a distance of 500 m was not reac…
Superficial Siderosis of the Central Nervous System associated with Hemophilia A: A case report
2021
Abstract Superficial Siderosis of the Central Nervous System (SSCNS) is a condition secondary to the deposition of hemosiderin within the subpial layers of central nervous system leading to its progressive degeneration, clinically responsible for hearing impairment, cerebellar ataxia and pyramidal syndrome. Here we report the case of a 61-year-old man with medical history of congenital hemophilia A presenting with typical clinical features of SSCNS associated with extensive hypo-intensity on fast 2D gradient-echo-weighted sequences, along the spinal cord, posterior fossa's structures and cerebral cortex. Interestingly, although his disorder was revealed by a lumbar spinal stenosis, presurgi…
Lumbar spinal stenosis: rehabilitation after surgery treatment
2012
After the preliminary outcomes obtained, we can assert that a post-operative rehabilitation program supplemented by an educational booklet, such as visual and mnemonic support, improves results of surgery of the spine, quality of life and maintains over time the well-being.
Preliminary experience with lumbar facet distraction and fixation as treatment for lumbar spinal stenosis
2017
Objectives: To assess the properties of facet fixation with the Facet Wedge system in patients affected by lumbar spinal stenosis (LSS). Summary of Background Data: Implant of intra-articular spacers is an emerging technique for lumbar degenerative disease. Methods: This study included forty patients (Group 1) with symptomatic LSS in whom intra-articular spacers have been implanted along with microdecompression (MD) of the neural structures. Group 1 has been compared with a homogeneous group of patients with LSS treated with MD without intra-articular spacers implant (Group 2). Clinical findings have been observed preoperatively and 3, 6, 12 months postoperatively using dedicated questionna…
Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.
2019
Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…